Fuses, Breakers and Isolators for 12V to 48V Solar

What each protective part does, where it goes in a DC solar system, and the mistakes that cause fires.

Batteries can deliver an enormous current into a short circuit, far more than a cable can carry. Fuses, breakers and isolators are what stop a fault turning into a fire. This guide covers the extra-low voltage DC side of a solar system.

1. What each part does

2. The golden rule: protect the cable

A fuse or breaker is there to protect the cable it feeds. Its rating must be at or below what that cable can safely carry. A fuse that's too big for its cable lets the cable overheat before the fuse blows.

3. Where protection goes

4. DC is not AC

5. Lithium batteries need a high-rated main fuse

A lithium (LiFePO4) bank can deliver thousands of amps into a dead short. The main fuse needs an interrupt rating high enough to break that current safely. Check the battery maker's manual for the fuse type and rating they specify, and follow it.

6. Cable size and voltage drop

Cable has to be thick enough to carry the current without overheating, and thick enough to keep voltage drop low. Voltage drop matters most on 12V systems, because a small drop is a big share of 12V. Use a cable sizing chart or calculator, with the full length of the run there and back.

7. Common mistakes

Safety: in Australia, any work on 240V AC wiring, including connecting an inverter, battery or solar system to a home's switchboard or fixed wiring, must be done by a licensed electrician. Grid-connected systems also need approval from your electricity network.